Match the model and controller
Include the complete unit designation and a photo of the control panel. Heat exchanger type, heating equipment and controls affect both maintenance and alarm interpretation. Do not treat C6, C6M and other control manuals as interchangeable without checking.
Installation planning considers room airflow rates, duct pressure losses, noise and service space. Select a unit by its operating point, not just maximum airflow. Replacements require checks of duct orientation, electrical supply and control connections.
Verified examples: C6.1 / C6.2 manual, 2025-02
Examples come from table 2.6.1 of the official C6.1/C6.2 manual. Use them only with the matching controller manual; these are not universal Komfovent codes.
- W1 – filter maintenance warning. Replace with suitable filters and follow the manual’s calibration procedure.
- F4 – supply air temperature too low. One possible cause is not a confirmed diagnosis.
- F6 – electric heater overheating. Do not reset protection before identifying and correcting the cause.
- F7 – heat exchanger alarm. The manual distinguishes the DOMEKT R rotor from the DOMEKT CF bypass damper.
An indicator on the simple C6.2 panel may require another control interface to read the exact message. Record the message and model; electrical and protection checks are for a specialist.
If the unit rumbles or heat recovery deteriorates
These are general symptoms. Check the operating mode and last filter change, and explain whether the change followed adjustments. The same symptom can have several causes. Cold supply air alone does not prove a failed rotor motor.
If the message persists, arrange diagnostics. Where needed, sensor readings, airflow rates and heat exchanger operation are assessed against the model’s design. We distinguish routine maintenance, diagnostics and potential repairs in the quote.
Komfovent installation and maintenance
We install and maintain Komfovent ventilation units in Tallinn and Harju County. We confirm the model, spare part availability and scope before agreement. New unit selection includes filter access and future maintenance.
Nordichooldus / NVAC OÜ provides independent installation and maintenance services. Manufacturer names identify the equipment and do not imply authorised representation, certification or a manufacturer partnership. Warranty claims must be coordinated with the seller or manufacturer.
Official sources
Manufacturer information checked on 8 October 2026. Before taking action, match the manual’s model, controller and revision to your unit. Manuals may subsequently change.