How ventilation works: heat recovery and air exchange

Ventilation exchanges indoor air for outdoor air. Results depend on the unit, ducts and free movement between rooms.

Air’s route through the home

Balanced mechanical ventilation usually supplies fresh air to living rooms and bedrooms and extracts used air from kitchens, bathrooms and toilets. Air moves between rooms through designed routes such as door undercuts or transfer grilles. Blocking them can reduce a room’s ventilation even while the unit runs.

Natural ventilation depends partly on indoor–outdoor temperature differences and wind. Mechanical extract also needs a designed replacement air route. A window gap does not automatically replace a designed supply system. Shared apartment shafts and rooftop fans must be considered together with the association.

What does heat recovery do?

Heat recovery uses outgoing air’s heat to preheat incoming air. It reduces ventilation heat loss but does not automatically make the unit the home’s main heater. Supply air may be cooler than room air in winter, depending on weather, flow, exchanger and heating equipment.

HRV and ERV differ: Airobot’s manual distinguishes heat recovery with HRV from additional partial moisture recovery with ERV. Moisture recovery is not a humidifier. These labels alone do not make all manufacturers’ solutions equivalent.

What do CO₂ and humidity indicate?

Rising bedroom CO₂ can indicate insufficient fresh air for the number of occupants. One reading does not identify the cause; sensor position, trends, occupancy and room airflow matter. Filter changes do not fix blocked transfer paths or incorrect flow settings.

Washing and cooking create moisture. Temporary boost helps remove it, but persistent condensation also requires assessing surface temperatures, moisture loads and air paths. Dry winter air does not necessarily mean a fault; do not arbitrarily reduce ventilation from humidity alone.

When should boost and away modes be used?

Use modes specified in the manual. Away mode reduces air exchange, but wet laundry, construction moisture or other moisture sources need separate assessment. Permanently switching ventilation off is not a normal energy-saving measure.

Do not change supply–extract balance or terminal settings without checking airflow. Fan speed percentages are not measured room airflow. If noise or draughts disturb you, have airflow and resistance checked.

Does an air conditioner bring in fresh air?

A conventional split air conditioner mainly recirculates indoor air for cooling or heating. An outdoor unit does not itself mean outdoor air is supplied indoors. Ventilation and cooling therefore need separate solutions. Some models have an outdoor air function; verify it in the specific model’s data.

Official sources

Manufacturer information checked on 8 October 2026. Before taking action, match the manual’s model, controller and revision to your unit. Manuals may subsequently change.